Skip to the content
Home » Blog » Aero-Gro 12V Timer

Aero-Gro 12V Timer

Programming Instructions

Instruction Manual:

Before using it, first remind the user to pay attention to it. After setting the data, you must wait for 6s. After 6s, the module will automatically save the data set in memory.

Short press the SET button once to enter the time setting mode, the red digital tube appears to flash, adjust the timing time T1 by pressing the plus or minus button, after setting T1, press the SET button again, the green digital tube flashes, and set the timing by pressing the plus and minus button Time T2, T2 time setting is completed, short press the SET button again, the system will automatically save the memory setting time or wait for 6s, after 6s the module will automatically memory to save data.

Long press SET to enter the parameter setting mode. There are two sets of parameters for users to choose P0 and P1. In the current mode, short press SET to switch between P0 and P1. Under the P0 parameter, you can set the timing mode that suits you by pressing the keys. Under the P1 parameter, you can set the working mode by pressing the keys.

P0–0: T1 timing time mode is second

P0–1: T1 timing time mode is minute

P0–2: T1 timing time mode is

P1–0: Relay pull-in after T1 time delay (T1 timing)

P1–1: The relay is released after the delay time T1 (T1 timing)

P1–2: After the delay time T1, the relay is closed (T1 timing), and after the delay time T2, the relay is released (T2 timing) and ends.

P1–3: After the delay time T1, the relay is released (T1 timing), and after the delay time T2, the relay is activated (T2 timing), and ends.

 P1–4: The relay pulls in after the delay of T1 time (T1 timing), and then releases after the delay of T2 time (T2 timing), and repeats the cycle.

 P1–5: The relay is released after the delay of T1 time (T1 timing), and then the relay is switched on after the delay of T2 time (T2 timing), and the cycle is repeated.

 An example: for example, a customer needs to turn on the computer for 10 seconds at a fixed time and turn off the computer for 20 seconds, and the cycle continues. The setting method is as follows:

T1 set time 10, T2 set time 20

 P0—0 (T1 timing range is in seconds)

 P1—5 (timer working mode is to stop after working and then keep looping)

Restoring the factory settings: The data is disordered due to wrong settings. When the settings cannot be set, you can choose to restore the factory settings, press and hold SET and then power on.

Product parameters:

Timing range: 0000 ~ 9999 seconds

       00: 00 ~ 99: 59 [Example-01:17 means 1 hour and 17 minutes; 10:02 means 10 hours and 2 minutes]

About timing settings: Timing 1 / Timing 2, different time units can be set at the same time [Example: Timing 1 is timed according to “hour”, Timing 2 is timed with “minute”; the three units of seconds / minutes / hours can be randomly combined]

Feature set: combination of 54 features

Power-off memory: power-off memory settings

Output type: direct output

Working power supply: DC12V / 20A / 240W (peak)

                   DC24V / 20A / 480W (peak)

                   AC110V ~ 220V / 10A / 2200W (peak value)

Product size: 67 × 45 × 34mm

Hole size: 63 × 42mm

Product weight: 58g (DC12V / DC24V)

                      63g (AC110 ~ 220V)